RC4500 Antenna Controller Chapter 5 MODES – In Depth Descriptions
118
5.2.2.3 Time Maintenance
The Time Maintenance screen allows the user to set the system and reference (see section 6.2.2) time.
Note that all dates are displayed and entered in day/month/year (DD/MM/YY) format. All times are
displayed and entered in hour/minute/second (HH:MM:SS) format. Refer to
section 2.1.2 for instructions
on entering date and time.
SYSTEM:11/10/97 22:26:40 TIME
DISPLAY:11/10/97 16:26:40 ZONE:UTC
OFFSET: 0
1-DATE 2-TIME 4-ZONE 5-OFFSET
SYSTEM:
Current date and time as maintained by the RC4500’s real-time clock.
DISPLAY:
Current “reference” time that will be displayed in several screens (MANUAL, MENU). This time is offset
from the system time by the OFFSET number of hours described later.
ZONE:
A three character alphanumeric time zone string the user may customize for displaying during the
MANUAL and MENU modes. This string may be changed by selecting action 4-ZONE.
OFFSET:
The number of hours the displayed reference time is offset from system time.
The values for the time parameters may be altered by the actions described next:
1-DATE ENTER DATE DD.MM.YY
This action allows the user to manually set the date. The prompt indicates that the / delimiter for date is
entered by using the (decimal point) key.
2-TIME ENTER TIME HH.MM.SS
This action allows the user to manually set the system time. The prompt indicates that the : delimiter for
time is entered by using the (decimal point) key.
4-ZONE ENTER
3 LETTER TIME ZONE
The user may enter three alphanumeric characters (ex. CST) for a time zone designator.
5-OFFSET ENTER
TIMEZONE OFFSET <-11/+12 HOURS>
The user may enter the number of hours of offset from system time for offsetting displayed time.