RC4500 Antenna Controller Chapter 2 Basic Operation
20
2.3 Programming Mode
The Programming Mode consists of the CONFIG mode and MAINT (maintenance) mode. These are the
two modes that will be used during installation and calibration of the RC4500. This section is intended to
be a very abbreviated guide to the Programming Mode screens and an in-depth description of each
screen should be reviewed in section 5.2 PROGRAMMING GROUP.
2.3.1 CONFIG Mode Basics
Configuration mode screens allow the user to customize and calibrate the operation of the RC4500 for
use with a particular mount. Note that most configuration items will be factory set for correct operation
with a particular mount.
EXPERT ACCESS PERMISSION CONFIG-MENU
TOGGLES EXPERT ACCESS ON & OFF
<SCR>THRU LIST <ENTER>SELECT <MODE>MAINT
Scroll UP/DN through Allows continuous
CONFIG screens cycle through screens
LOCATION RESET CONFIG-MENU
RESET ANTENNA LOCATION
<SCR>THRU LIST <ENTER>SELECT <MODE>MAINT
Modifications of CONFIG mode items should be performed according to the installation and calibration
procedures in
Chapter 4. A full detailed description of the CONFIG mode and all sub-modes can be found
in section 5.2.1.
From the CONFIG screen, momentarily pressing the Mode key will move to MAINT (maintenance) mode.
2.3.2 MAINTENANCE Mode Basics
The maintenance mode screen allows the user to monitor sensor inputs and perform periodic
maintenance actions such as setting time and resetting drive errors.
A full detailed description of the MAINT mode screen can be found in
section 5.2.2.
1-VOLTS 2-DRIVE 3-TIME MAINT
5-LIMITS
0-SHAKE
^-RES OFF .-SYS INFO
From the MAINT screen, momentarily pressing the Mode key will move to the CONFIG mode