RC4500 Antenna Controller Chapter 3 Mechanical & Electrical Installation
43
3.3.2.3 I/O and Limits
The I/O and Limits cable is used by the RC4500 to interface with the AIU relay board primarily to produce
drive commands and receive limit switch status. A cable such as Belden 9948 (RCI p/n CBL-25_22) is
used.
Polarization CW Limit input, 24 VDC low current
(0V = POL CW Limit reached)
Polarization CCW Limit input, 24 VDC low current
(0V = POL CCW Limit reached)
Elevation Up Limit input, 24 VDC low current
(0V = EL Up Limit reached)
Elevation Down Limit input, 24 VDC low current
(0V = EL Down Limit reached)
Azimuth CW Limit input, 24 VDC low current
(0V = AZ CW Limit reached)
Blue / Black Azimuth CCW Limit input, 24 VDC low current
(0V = AZ CCW Limit reached)
J6 pin 9
Elevation Fast command, pull-down drive, 70mA max sink
(1.5V = EL Fast)
Azimuth Fast command, pull-down drive, 70mA max sink (1.5V
= AZ Fast)
Polarization CW command, pull-down drive, 70mA max sink
(1.5V = move CW)
Black / White Polarization CCW command, pull-down drive, 70mA max sink
J4 pin 4
Elevation Up command, pull-down drive, 70mA max sink (1.5V
= move Up)
Elevation Down command, pull-down drive, 70mA max sink
(1.5V = move Down)
Green / Black Azimuth CW command, pull-down drive, 70mA max sink (1.5V
J4 pin 7
Azimuth CCW command, pull-down drive, 70mA max sink
(1.5V = move CCW)
Drive Common (return path for AZ, EL and POL drive command
lines)
Drive Common (return path for AZ, EL and POL drive command
lines)
Green / White Drive Enable command, pull-down drive, 70mA max sink (1.5V
J4 pin 11
Elevation Drive Fault input, 24 VDC low current
(0V = drive fault)
Azimuth Drive Fault input, 24 VDC low current
(0V = drive fault)
Emergency Stop status input, 24 VDC low current (0V =
Emergency STOP)
Emergency Stop status return
Black / White / Red Maintenance status input, 24 VDC low current (0V =
Maintenance – pedestal jogging)
<2>
J19 pin 3
Maintenance status return
<1> “Limit Return” is the common return for all EL, AZ and POL limits.