EasyManua.ls Logo

RESEARCH CONCEPTS RC4500 - Define System Time

RESEARCH CONCEPTS RC4500
141 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RC4500 Antenna Controller Chapter 4 Software Configuration / Installation
62
4.1.4 Define System Time
An additional recommended step is to set the date/time within the ACU. The Date/Time will be set to UTC
at the factory but the internal clock may drift several seconds per month.
Go to the MAINTENANCE TIME screen to check and set the date and time. Accurate date/time is
particularly important for installations performing Two Line Element (TLE) tracking.
Note that all dates are displayed and entered in day/month/year (DD/MM/YY) format. All times are
displayed and entered in hour/minute/second (HH:MM:SS) format. Refer to
section 2.1.2 for instructions
on entering date and time.
SYSTEM:11/10/97 22:26:40 TIME
DISPLAY:11/10/97 16:26:40 ZONE:UTC
OFFSET: 0
1-DATE 2-TIME 4-ZONE 5-OFFSET

Table of Contents