EasyManua.ls Logo

RESEARCH CONCEPTS RC4500 - Auxiliary I;O

RESEARCH CONCEPTS RC4500
141 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RC4500 Antenna Controller Chapter 3 Mechanical & Electrical Installation
25
3.1.2.3 Auxiliary I/O
J6 is a 25 pin D-subminiature female receptacle used for Antenna Auxiliary I/O. This port supports
isolated, axis-specific limit inputs as well as contact closures for peripheral equipment control. A +24 VDC
unregulated output (750mA max) referenced to the RC4500 chassis ground, is also available.
Each limit input on connector J6 is rated for 24VDC and draws approximately 5mA @ 24VDC input.
Pin #
1
Description
Relay 1 COM
2 Relay 1 NO
3 Azimuth CW Limit Return
4 Azimuth CCW Limit Return
5 Elevation Down Limit Return
6 Elevation Up Limit Return
7 Polarization CW Limit Return
8 Polarization CCW Limit Return
9 Drive Common (return path, same as J7 pins 2, 5, 8)
10 Relay 0 NC
11 NC
12 NC
13 Ground for system bus voltages
14 Relay 1 NC
15 Azimuth CW Limit input, 24 VDC low current (0V = AZ CW Limit reached)
16 Azimuth CCW Limit input, 24 VDC low current (0V = AZ CCW Limit reached)
17 Elevation Down Limit input, 24 VDC low current (0V = EL Down Limit reached)
18 Elevation Up Limit input, 24 VDC low current (0V = EL Up Limit reached)
19 Polarization CW Limit input, 24 VDC low current (0V = POL CW Limit reached)
20 Polarization CCW Limit input, 24 VDC low current (0V = POL CCW Limit reached)
21 NC
22 Relay 0 COM
23 Relay 0 NO
24 NC
25
Unregulated +24 VDC bus voltage, 750mA max.

Table of Contents