Bosch Rexroth Canada ı May.2018 ı Revision 7.0
Liquid Material Calibration (Prewet or Anti-icing)
1. Tap on symbol and PREWET/NORM tab to enter into liquid calibration.
2. Place an adequate catch container under the liquid spray nozzle.
3. Make sure that sufficient liquid in the tank and the system is safe to run.
4. Press “CALIBRATION” button to proceed.
5. Turn PREWET Knob to run.
6. Stop when desired amount is reached.
7. Measure the liquid volume and enter the value.
8. Press “CALIBRATION” Button to complete.