12 Material Catch Test
1. Tap on symbol to enter into the material calibration screen.
2. Place an adequate catch container under the spreader discharge chute.
3. Press “CATCH TEST” button to start, and enter the desired rate, speed and duration
(seconds) using on-screen keypad.
4. Press “CATCH TESTbutton to begin material dispensing (hydraulics must be active).
5. When dispensing is stopped, weigh the material and enter the value.
6. Press “CATCH TEST” button again to end.
7. A wt/rev will be calculated and displayed on the bottom right of the screen.
8. Repeat this procedure for all solid materials (use the green left and right arrows to
select material types).
9. Rates can be adjusted by tapping the rate and editing the value with the keypad.
10. These same procedures apply to pre-wet and liquid. Note: Granular spread rate is
defaulted to 2000 lbs/Mile.
Note: The material names can be changed by tapping on the text “SALT - -and using the
keypad to edit.