Bosch Rexroth Canada ı May.2018 ı Revision 7.0
Error 51 - Anti-Ice Pulses per Gallon Too Low. During calibration of anti-ice volume output,
the pulses/gal was too low, most likely caused by no flow sensor feedback.
Error 52 - Anti-Ice Pulses per Gallon Too Hi. During calibration of anti-ice volume output,
the pulses/gal was too high, most likely caused by typing in zero for the volume.
Error 53 - Spinner mm at zero RPM too Low. During calibration of the relationship between
spinner RPM and spinner spread width, a value of 0 mm at zero RPM was used.
Error 54 - Spinner mm per RPM too Low. During calibration of the relationship between
spinner RPM and spinner spread width, a value of maximum spread width was used that
was less than the mm at zero RPM.
Error 55 - Gate Movement Too Low. During calibration of gate maximum and minimum
position, the difference between minimum and maximum height was less than 1 inch.
Error 57 - Gate at Calibration Too Low. While calibrating the weight per revolution for a
specific material, the gate position at calibration was specified to be zero.
Error 58 - Spinner PPR Too Low. A value of zero was used for spinner pulses per
revolution.
Error 59 - Conveyor PPR Too Low. A value of zero was used for conveyor pulses per
revolution.
Error 60 - Spinner Output Range Too Low. The difference between maximum and
minimum spinner nulling values was less than 5%.
Error 61 - Conveyor Output Range Too Low. The difference between maximum and
minimum conveyor nulling values was less than 5%.
Error 62 - Cross Conveyor 1 Output Range Too Low. The difference between maximum
and minimum cross conveyor nulling values was less than 5%.
Error 63 - Cross Conveyor 2 Output Range Too Low. The difference between maximum
and minimum cross conveyor nulling values was less than 5%.
Error 64 - Pre-Wet Output Range Too Low. The difference between maximum and
minimum pre-wet nulling values was less than 5%.
Error 65 - Anti-Ice Output Range Too Low. The difference between maximum and
minimum anti-ice nulling values was less than 5%.
Error 66 - Joystick 1 Output Range Too Low. The difference between maximum and
minimum joystick nulling values for one of the six outputs was less than 5%.
Error 67 - Joystick 2 Output Range Too Low. The difference between maximum and
minimum joystick nulling values for one of the six outputs was less than 5%.
Error 68 - Theoretical Maximum Conveyor RPM Too High. Based on the specified
application rate setpoints, and the maximum ground speed, the maximum theoretical
conveyor RPM required has been calculated to be more than twice the actual conveyor
capacity, which will lead to serious under-application problems. The actual controller RPM
setpoint will be clamped at this value to prevent the controller from becoming unstable, and
the conveyor should be re-calibrated to determine the source of the problem.