Code Name Setting range Default Min. Attri.
E0.72 Skip frequency 3 0.00...[E0.09] Hz 0.00 0.01 Stop
E0.73 Skip frequency range 0.00...30.00 Hz 0.00 0.01 Stop
E0.74
Skip window acceleration
factor
1...100 1 1 Stop
: percentage of frequency converter rated current.
Setting range of E0.00, E0.02:
0: Panel potentiometer
1: Panel button setting
2: AI1 analog input
3: AI2 analog input
4: EAI1 analog input
5: EAI2 analog input
10: X5 pulse input
11: Digital input Up / Down command
20: Communication
21: Multi-speed settings
Setting range of E0.01, E0.03:
0: Panel
1: Multi-function digital input
2: Communication
Setting range of E0.04:
0: No combination
1: First frequency setting + second frequency setting
2: First frequency setting - second frequency setting
3: First frequency setting x second frequency setting
4: Bigger one of 2 sources
5: Smaller one of 2 sources
6: Valid which channel is non-zero
Setting range of E0.06:
0: Not saved when powered off or stopped
1: Not saved when powered off; saved when stopped
2: Saved when powered off; not saved when stopped
3: Saved when powered off or stopped
4: Memorized automatically when stopped