SP5xxx: Mode
SM 5-73 D017/D018/D019/D020
Service
Tables
[0 to 2/1]
0: Yes. Normal reset
1: Standby. Resets before job start/after completion
2: No. Normally no reset
Counter Up Timing
5121
Determines whether the optional key counter counts up at paper feed-in or at
paper exit. Japan Only
[0 to 1/1]
0: Feed count
1: No feed count
F Size Original Setting
5126
Selects the F-size original setting.
[0 to 2 / 0 / 1 /step]
0: 81/2" x 13" (Foolscap)
1: 81/4" x 13" (Folio)
2: 8" x 13" (F)
APS OFF Mode
5127
This SP can be used to switch APS (Auto Paper Select) off when a coin lock or
pre-paid key card device is connected to the machine.
[0 to 1/1]
0: On
1: Off
F Paper Size Selection
5129*
Selects the âFâ paper size.
[0 to 2 / 0 / 1 step]
0: 8" x 13"
1: 8.5" x 13"