EasyManua.ls Logo

Ricoh BE-C1 D046 - Page 496

Ricoh BE-C1 D046
734 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fusing lamp harness loose, broken, defective
IOB defective
SC546 A
Unstable fusing temperature
Fusing temperature fluctuated more than 20°C (68°F) within 1 sec. more than 7
times during the previous 60 sec. of fusing temperature control.
Thermistor disconnected
Thermistor out of position, not in contact with hot roller
Thermistor connection loose, broken, defective
SC547 D
Zero-cross signal error
One of the following conditions occurred:
No zero-cross signal detected within 50 ms after the machine was powered
on with Relay 0 off, or abnormal zero-cross detected 3 times.
No zero-cross signal detected for 3 sec. after fusing relay turned on after power
on.
Abnormal mains frequency was detected more than 10 times.
Electrical noise on the power line
PSU power relay defective.
SC551 A
Pressure roller center thermistor error 1
The thermistor returned temperature readings less than 5°C (41°F) for 12 sec.
during fusing temperature control while the hot roller and pressure rollers were
rotating
Thermistor connection loose, broken, defective
Thermistor floating free, not positioned correctly
Thermistor defective
IOB defective
SC553 A
Pressure roller center thermistor error
During fusing temperature control the thermistor at the center of the pressure roller
returned an abnormally low reading.