EasyManua.ls Logo

Ricoh BE-C1 D046 - Page 501

Ricoh BE-C1 D046
734 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SC634 B
Key/card counter device error 3 GW
The backup battery of the counter device RAM is low.
Replace the RAM backup battery.
SC635 B
Key/card counter device error 4 GW
After installation of the device, a message alerts user to a battery voltage abnormal
error.
Device control board defective
Device control board backup battery defective
SC636 B
Expansion recognition module error GW
An error has occurred while trying to access the file of the expansion recognition
module.
DESS module does not exist on SD card
External expansion recognition module does not exist on SD card
SD card damaged
External expansion recognition file corrupted
SC641 B
Engine-to-controller communication error: No response GW
The controller sent a frame to the main machine engine but there was no response
as demanded by RAPI protocol. The frame was sent 3 times at 100 ms intervals. This
SC was issued after the 3rd attempt failed.
Examine the connection between the controller and the engine board.
Replace the engine board if the error is frequent.
SC650 B
Cumin-M communication error GW
An error occurred with the Cumin modem (dialup, modem port) when the machine
was switched on.
The settings for @Remote SP5816 are incorrect
Modem disconnected from the phone line
Modem port disconnected