Setting Power
0 Low power (2.02V)
1 Medium low power (2.20V)
2 Medium high power (2.50V)
3 High power (2.77V)
32
Fold Motor Power: Paper Folding
This SP sets the amount of voltage fed to the cross fold motor until the 2nd fold is done in the
cross folder unit.
[0 to 3/0/1]
Setting Power
0 Low power (2.02V)
1 Medium low power (2.20V)
2 Medium high power (2.50V)
3 High power (2.77V)
41
Fold Length: 1st Fold Peak
This SP adjusts the length of the fold by the lower fold length sensor.
This is applied to the 1st peak fold. The width of the folded surface can be adjusted in the range
±20 mm. Raising the setting increases the width of the fold.
[-20 to +20/-6.5/0.5 mm]
42
Fold Length: 1st Fold Valley
This SP adjusts the length of the fold by the upper fold length sensor.
This is applied to the 1st valley fold. The width of the folded surface can be adjusted in the range
±20 mm. Raising the setting increases the width of the fold.
[-20 to +20/-6.5/0.5 mm]
51
1st Fold
The width of the 1st folded surface can be adjusted in the range ±10 mm. Raising the setting
increases the width of the fold.
[-10 to +10/0/0.5 mm]
52
Cross 2nd Fold
System Service Mode