SP Table
SM Appendix 35 C279
Appendix:
Service
Program
Mode Tables
6-60
Master returning value
[0 to 200 / 100 / 0.1mm]
The auto adjustable master set mechanism automatically moves the leading
edge of the master to the correct position after the user installs a master roll.
This position can be adjusted with SP 6-60. This SP adjusts the amount that the
machine feeds the master after it detects the leading edge of the master.
Bigger number: increases feeding
Smaller number: decreases feeding
6-61 Master length - A3 drum
[4200 to 6000 / 5400 / 0.1mm]
6-63 Master length - A4 drum
[3000 to 6000 / 3400 / 0.1mm]
6-64
Master pushing value
[0 to 100 / 50 / pulse]
This adjusts the pressure between the master push Mylar and the drum.
Bigger number: increases the pressure
Smaller number: decreases the pressure
6-70 Trial pressure:low temp
[1 to 5 / 2 / -]
6-71 60 rpm pressure:low temp
[1 to 5 / 1 / -]
6-72 75 rpm pressure:low temp
[1 to 5 / 3 / -]
6-73 90 rpm pressure:low temp
[1 to 5 / 4 / -]
6-74 105rpm pressure:low temp
[1 to 5 / 5 / -]
6-75 130rpm pressure:low temp
[1 to 5 / 5 / -]
Adjust the pressure each print speed in low temperature (below 15 °C).
6-76 Trial pressure:normal temp
[1 to 5 / 2 / -]
6-77 60rpm pressure:normal temp
[1 to 5 / 1 / -]
6-78 75rpm pressure:normal temp
[1 to 5 / 2 / -]

Table of Contents