Master returning value   
[0 to 200 / 100 / 0.1mm] 
The auto adjustable master set mechanism automatically moves the leading 
edge of the master to the correct position after the user installs a master roll. 
This position can be adjusted with SP 6-60. This SP adjusts the amount that the 
machine feeds the master after it detects the leading edge of the master. 
Bigger number: increases feeding 
Smaller number: decreases feeding 
6-61  Master length - A3 drum   
[4200 to 6000 / 5400 / 0.1mm] 
     
6-63  Master length - A4 drum   
[3000 to 6000 / 3400 / 0.1mm] 
6-64 
Master pushing value   
[0 to 100 / 50 / pulse] 
This adjusts the pressure between the master push Mylar and the drum. 
Bigger number: increases the pressure 
Smaller number: decreases the pressure 
     
6-70  Trial pressure:low temp   
[1 to 5 / 2 / -] 
6-71  60 rpm pressure:low temp   
[1 to 5 / 1 / -] 
6-72  75 rpm pressure:low temp   
[1 to 5 / 3 / -] 
6-73  90 rpm pressure:low temp   
[1 to 5 / 4 / -] 
6-74  105rpm pressure:low temp   
[1 to 5 / 5 / -] 
6-75  130rpm pressure:low temp   
[1 to 5 / 5 / -] 
Adjust the pressure each print speed in low temperature (below 15 °C). 
     
6-76  Trial pressure:normal temp   
[1 to 5 / 2 / -] 
6-77  60rpm pressure:normal temp   
[1 to 5 / 1 / -] 
6-78  75rpm pressure:normal temp   
[1 to 5 / 2 / -]