SP Table
C279 36 SM Appendix
6-79 90rpm pressure:normal temp
[1 to 5 / 3 / -]
6-80 105rpm pressure:normal temp
[1 to 5 / 4 / -]
6-81 130rpm pressure:normal temp
[1 to 5 / 5 / -]
Adjust the pressure each print speed in normal temperature (15 to 28 °C).
6-82 Trial pressure:high temp
[1 to 5 / 2 / -]
6-83 60 rpm pressure:high temp
[1 to 5 / 1 / -]
6-84 75 rpm pressure:high temp
[1 to 5 / 1 / -]
6-85 90 rpm pressure:high temp
[1 to 5 / 2 / -]
6-86 105rpm pressure:high temp
[1 to 5 / 3 / -]
6-87 130rpm pressure:high temp
[1 to 5 / 5 / -]
Adjust the pressure each print speed in high temperature (over 28 °C).
6-90 Analog Gain Adjustment:RED
[0 to 7 / 0 / -]
6-91
Analog Gain
Adjustment:GREEN
[0 to 7 / 0 / -]
6-92 Analog Gain Adjustment:BLUE
[0 to 7 / 0 / -]
Display the SBU adjustment(AGC)result when turn on.
6-93 Digital Gain Adjustment:RE
[0 to 1023 / 81 / -]
6-94 Digital Gain Adjustment:RO
[0 to 1023 / 81 / -]
6-95 Digital Gain Adjustment:GE
[0 to 1023 / 70 / -]
6-96 Digital Gain Adjustment:GO
[0 to 1023 / 70 / -]
6-97 Digital Gain Adjustment:BE
[0 to 1023 / 73 / -]