SERVICE RAM ADDRESSES 30 November, 1999
4-56
800271 to 800273(H)
- Effective term of automatic service calls
Parameters Address (H)
Year: last two digits of the year (BCD) 800271
Month: 01 through 12 (BCD) 800272
Day: 01 through 31 (BCD) 800273
800274(H)
-
MODEM
version (Read only)
800274(H) - Low (hex)
800275(H) - High (hex)
8002B6 to 8002B7(H)
- Scanning top margin adjustment
8002B8 to 8002B9 (H)
- Scanning bottom margin adjustment
Refer to section 6.12 for details.
80034E(H) - Excessive jam alarm
Bit 3: Scanner excessive jam alarm 1: An alarm has occurred
Bit 4: Printer excessive jam alarm 1: An alarm has occurred
Either or both of these bits will change to 1 when an excessive jam alarm occurs.
Reset each bit to 0 when you have solved the problem. The machine will not be
able to detect excessive jams in future if you do not reset these bits.
80035F(H)
- Print top margin (standard cassette: factory mode)
800360(H)
- Print top margin (optional paper feed unit: factory mode)
80036B(H)
- Print left margin (standard cassette: factory mode)
80036C(H)
- Print left margin (optional paper feed unit: factory mode)
800375(H)
- Print top margin (standard cassette: user function mode)
800376(H)
- Print top margin (optional paper feed unit: user function mode)
80037E(H)
- Print left margin (standard cassette: user function mode)
80037F(H)
- Print left margin (optional paper feed unit: user function mode)
Refer to section 6.12 for details about these parameters.