2. Margins (Sub Scan Direction)
Parameter Formula
RAM
Address
Unit
Initial
Setting
L1
H545R562.WMF
To increase the margin by x mm:
New setting = Current setting + x/0.46
To decrease the margin by x mm:
New setting = Current setting - x/0.46
When the user sets the margin in the sub-
scan direction with a User Function, the
margin is added to this setting.
Standard
cassette:
80035F(H)
Optional
paper feed
unit:
800360(H)
Optional
multi
purpose
feeder:
800364(H)
0.46
mm
0B(H)
0B(H)
0B(H)
L2
Not adjustable
L3
Not adjustable