30 November, 1999 ERROR CODES
7-27
Trouble-
shooting
Code Meaning Suggested Cause/Action
0-06
The other terminal did not
reply to DCS
Check the line connection.
Check the FCU - NCU connectors.
Try adjusting the TX level and/or cable equalizer
settings.
Replace the NCU or FCU.
The other end may be defective or incompatible;
try sending to another machine.
Check for line problems.
Cross-reference
See error code 0-04.
0-07 No post-message
response from the other
end after a page was sent
Check the line connection.
Check the FCU - NCU connectors.
Replace the NCU or FCU.
The other end may have jammed or run out of
paper.
The other end user may have disconnected the
call.
Check for a bad line.
The other end may be defective; try sending to
another machine.
0-08 The other end sent an
RTN or PIN after receiving
a page, because there
were too many errors
Check the line connection.
Check the FCU - NCU connectors.
Replace the NCU or FCU.
The other end may have jammed, or run out of
paper or memory space.
Try adjusting the TX level and/or cable equalizer
settings.
The other end may have a defective
modem/NCU/FCU; try sending to another
machine.
Check for line problems and noise.
Cross-reference
TX level - NCU Parameter 01 (PSTN), RAM
807FB7 (PABX)
Cable equalizer - G3 Switch 07 (PSTN), G3
Switch 08 (PABX)
Dedicated TX parameters - Section 4-4
0-14 Non-standard post-
message response code
received
Check the FCU - NCU connectors.
Incompatible or defective remote terminal: try
sending to another machine.
Noisy line: re-send.
Try adjusting the TX level and/or cable equalizer
settings.
Replace the NCU or FCU.
Cross-reference: See error code 0-08.
0-15 The other terminal is not
capable of a certain
function
The other terminal does not have the SEP or
SUB function.
0-17 Pressing the Stop key
interrupts communication.
If the Stop key was not pressed and this error
keeps occurring, replace the operation panel or
OPU.