PRINTING 30 November, 1999
2-26
Fusing Unit Service Call Conditions
Conditions Error Code (9-22)
If there is a problem with the thermistor.
(Also for when the machine returns to Normal
Mode from Energy Saver Mode Level 2.)
Sub-code 09At power on
If the machine detects that both jumper 63 and
jumper 64 are shorted. *[The status of the
jumpers determines the model type. (USA,
Europe/Asia, Japan)]
Sub-code 0B
Standby mode
If the fusing temperature stays below 70 °C for
more than 36 seconds after selecting fusing
lamp ON in Energy Saver Mode Level 1 or when
in Standby Mode.
Sub-code 05
If the fusing temperature takes more than 60
seconds to reach 145°C from the standby
temperature.
Sub-code 02
Either: If the fusing temperature stays above
110°C for more than 180 seconds after selecting
the power saver standby temperature of 80°C
for Energy Saver Mode Level 1.
Or: If the fusing temperature stays above 175°C
for more than 180 seconds after selecting the
power saver standby temperature of 145°C for
Energy Saver Mode Level 1.
Sub-code 0A
If the fusing temperature is above 190°C for
more than 180 seconds.
Sub-code 01
If the fusing temperature is below 150 °C for
more than 180 seconds.
Sub-code 06
During printing
If the fusing temperature is below 140 °C for
more than 1 second.
Sub-code 07
After printing
If the fusing temperature takes more than 20
minutes to return to 100°C when the machine
goes into Energy Saver Mode Level 2. (After
selecting fusing lamp Off for Energy Saver Mode
Level 2.)
Sub-code 03
Either: If the fusing temperature takes more than
20 minutes to go down to below 100 °C when
the machine goes into the Energy Saver Mode
Level 2. (After selecting the standby temperature
of 80 °C for Energy Saver Mode Level 2.)
Or: If the fusing temperature takes more than 5
minutes to go down to 165 °C after selecting the
standby temperature for Energy Saver Mode
Level 1.
Sub-code 04
At any time
If the fusing temperature reaches 250°C.
Sub-code 08