Protocol Definition
Training Retries
This sets the number of training retries to be repeated
before automatic fallback.
[1 Time/ 2 Times (Default)/ 3 Times/ 4 Times]
Encoding
Sets the compression method for Tx/Rx.
[MMR+MR+MH (Default)/ MR+MH/ MH]
Protocol Definition
Timer
T0 Timer
Timeout for response from the called station in automatic
sending mode
[35 Sec/ 45 Sec/ 55 Sec/ 60 Sec(Default)/ 90 Sec/
140 Sec]
T1 Timer
Set the time length for the T1 timer.
[40 Sec (Default)/ 50 Sec]
T4 Timer
Set the time length for the T4 timer.
[3 Sec (Default/ 4.5 Sec]
RX Settings
Silence Detection
Silence (No tone) detection time (Rx mode : FAX/ TAD
Only)
After the line is connected via the external telephone, the
machine can detect silence (no tone) for the time length
specified by this setting.
[30 sec (Default)]
CNG Tone
Detection Time
CNG tone detection time ( RX mode : FAX / TEL, FAX /
TAD Only)
After the line is connected via the external telephone, the
machine can detect a CNG signal for the time length
specified by this setting.
[5 Sec (Default)/ 10 Sec]
CNG Cycles
Number of CNG cycles to be detected
This setting is only effective for FAX/TAD mode.
[1.5 Cycle (Default)/ 2.0 Cycle]
Tone Sound
Monitoring
Determines the period when tones from the line are
monitored.
[No Monitoring/ Up To Phase B (Default)/ All TX
Phases]
Service Menu