20152192
70
List of parameters PME71.901...
Tab. AD
680.00
Speed interval for constant time PT1: Upper
speed interval threshold
Modification 800 rpm
9000 rpm
10 rpm 4000 rpm SO OEM
680.01
Speed interval for constant time PT1: Lower
speed interval threshold
Modification 800 rpm 9000 rpm 10 rpm 2000 rpm SO OEM
700
Error history
701.00
Current error: Error code
Reading only 2 255 1 --- Service ---
701.01
Current error: Start-up meter reading
Reading only 0 999999 1 --- Service ---
701.02
Current error: MMI phase
Reading only --- --- --- --- Service ---
701.03
Current error: Power value
Reading only 0% 100% 1 --- Service ---
702.00
Error history former 1: Error code
Reading only 2 255 1 --- Service ---
702.01
Error history o1: Start-up meter reading
Reading only 0 999999 1 --- Service ---
702.02
Error history o1: MMI phase
Reading only --- --- --- --- Service ---
702.03
Error history o1: Power value
Reading only 0% 100% 1 --- Service ---
•
•
•
711.00
Error history former 10: Error code
Reading only 2 255 1 --- Service ---
711.01
Error history former 10: Start-up meter reading
Reading only 0 999999 1 --- Service ---
711.02
Error history former 10: MMI phase
Reading only --- ---
---
--- Service ---
711.03
Error history former 10: Power value
Reading only 0% 100% 1 --- Service ---
900
Process data
920
Current PWM signal fan
Reading only 0% 100% 1% --- Service ---
936
Normalized speed
Reading only 0% 100% 0.01% --- Service ---
951
Mains voltage
Reading only 0 V
LME 71.000
A1: 175 V
LME 71.000
A2: 350 V
1 V --- Service ---
954
Flame intensity
Reading only 0% 100% 1% --- Service ---
Parameter
Modification
Values interval
Resolution
Factory
setting
Password
reading
level to
level
Password
writing level
to level
Nr. Description Min. Max.