RIGOL
© 2008 RIGOL Technologies, Inc.
User‟s Guide for Logic Signal Output Module
2-11
Then the output would be: (Z indicates high Z)
D0: 1 0 0 1 1 0 0 1 0 1 0 1 0 1 0 0 0 0 1 0 0 1 0 0
D1: Z 1 0 Z Z 1 0 Z 0 Z 0 Z 0 Z 0 1 0 1 Z 1 0 Z 0 1
D5: Z 0 1 Z Z 0 1 Z 1 Z 1 Z 1 Z 1 0 1 0 Z 0 1 Z 1 0
NOTE
Only one of the channels (D0~D15) can be chosen as the Mask Channel.
The selected channel turns azury on the screen (See page 2-41, Figure
2-45 Channel marks).
Users can choose one or more channel as the Tri-state Channel. The
selected channels turn bolarious on the screen (See page 2-41, Figure 2-45
Channel marks).
Both the opening (yellow on the screen) and the closed (white on the
screen) channels can be chosen as the Mask Channel or the Tri-state
Channel. The difference is that the opening channel can output but not the
closed channel. To know how to open or close the channel, see page 2-42,
Table 2-12(1) Operation menu description.