RIGOL
© 2008 RIGOL Technologies, Inc.
User‟s Guide for Logic Signal Output Module
2-36
The Channel setting menu of RS232 protocol and operation description are shown
in the following figure and table.
Figure 2-39 Table 2-9 Operation menu description
PROMPT
Since RS232 voltage is negative logic and has negative voltage. While digital
channel cannot output negative voltage, just enable analog voltage and always
close digital channel.
Menu
Setting
Description
TX
D0
D1
D14
D15
Select data line of RS232.
Analo-volt
On
Off
Set analog channels voltage.
DONE
Store all the changes and return
the previous level menu.