RIGOL
© 2008 RIGOL Technologies, Inc.
User‟s Guide for Logic Signal Output Module
2-42
The Channel setting menu of PO protocol and operation description are shown in
the following figures and tables.
Figure 2-46(1) Table 2-12(1) Operation menu description
Figure 2-46(2) Table 2-12(2) Operation menu description
Menu
Setting
Description
DataLine
D0
D15
ALL
Select data line of PO.
Open
Close
To confirm whether output the
selected channel or not.
Open denotes output.
Close denotes do not output.
SCLK
C0
C1
Select clock line of PO.
Phase
0
90
180
270
Select the clock phase.
Menu
Setting
Description
Digit-Volt
1.8V
2.5V
3.3V
4.0V
User
Off
Set digital channels voltage. The
default is 3.3V.
User-defined mode (1.4V4.2V)
Turn off digital voltage output.
Analo-Volt
On
Off
Set analog channels voltage.
DONE
Store all the changes and return
the previous level menu.