EasyManuals Logo

Rigol MSO5074 User Manual

Rigol MSO5074
372 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
Contents RIGOL
MSO5000 User Guide XVII
Abs .............................................................................................. 6-20
Low Pass ....................................................................................... 6-21
High Pass ...................................................................................... 6-22
Band Pass ..................................................................................... 6-23
Band Stop ..................................................................................... 6-24
AX+B ............................................................................................ 6-25
Math Operation Label ..................................................................... 6-26
Auto Measurement ............................................................................... 6-27
Quick Measurement after AUTO....................................................... 6-27
Measurement Parameter ................................................................. 6-30
Measurement Settings .................................................................... 6-36
Remove the Measurement Result ..................................................... 6-39
Statistical Function ......................................................................... 6-39
All Measurement ............................................................................ 6-40
Cursor Measurement............................................................................. 6-40
Manual Mode ................................................................................. 6-42
Track Mode ................................................................................... 6-46
XY Mode ....................................................................................... 6-48
Measure Mode ............................................................................... 6-50
Chapter 7 Digital Voltmeter (DVM) and Frequency Counter .............. 7-1
Digital Voltmeter (DVM) ......................................................................... 7-2
To Enable or Disable DVM Measurement............................................ 7-2
To Select the Measurement Source ................................................... 7-2
To Select Measurement Mode ........................................................... 7-3
To Set the Limits ............................................................................. 7-3
Frequency Counter ................................................................................ 7-4
To Enable or Disable the Frequency Counter ...................................... 7-4
To Select the Measurement Source ................................................... 7-4
To Select the Measurement Item ...................................................... 7-4
To Set Resolution ............................................................................ 7-5
To Clear Count ................................................................................ 7-5
To Enable or Disable the Statistical Function ...................................... 7-5
Chapter 8 Power Analysis (Option) ................................................... 8-1
Power Quality ....................................................................................... 8-2
Ripple .................................................................................................. 8-4
Chapter 9 Histogram Analysis ........................................................... 9-1
To Enable or Disable the Histogram Function ............................................ 9-2
To Select the Histogram Type ................................................................. 9-2
To Select the Histogram Source .............................................................. 9-3
To Set the Histogram Height ................................................................... 9-3
To Set the Histogram Range ................................................................... 9-3
To Enable or Disable the Statistical Function............................................. 9-3
To Reset ............................................................................................... 9-4
Chapter 10 Digital Channel ............................................................... 10-1

Table of Contents

Other manuals for Rigol MSO5074

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol MSO5074 and is the answer not in the manual?

Rigol MSO5074 Specifications

General IconGeneral
Bandwidth70 MHz
Channels4
Timebase Accuracy± 2 ppm
Operating Temperature0 °C to +40 °C
Display800x480
Waveform Capture Rate500, 000 wfms/s
Vertical Resolution8 bits
InterfacesUSB Host, USB Device, LAN, HDMI
Input Impedance1 MΩ
Trigger TypesEdge, Slope, Pulse, Video, Pattern, Duration, Timeout, Window, Runt
Sample Rate8 GSa/s

Related product manuals