RIGOL Chapter 4 Functions of the Front Panel of EMI
4-18 RSA3000E User Guide
Trace Display
Enables or disables the trace display.
Remarks:
The trace state and the parameter settings for the corresponding state are as
follows:
Active: Trace Update and Trace Display are "On".
View: Trace Update is "Off", and Trace Display is "On".
Clear: Trace Update and Trace Display are "Off".
Back-end: Trace Update is "On", and Trace Display is "Off".
In most cases, the inactive trace data keep unchanged. However, the data may
be changed in the following conditions:
Load the stored data to trace.
Trace data are cleared by the trace clear function.