EasyManua.ls Logo

Rockwell Automation RELIANCE ELECTRIC SP500 - 2.2 Drive Description

Rockwell Automation RELIANCE ELECTRIC SP500
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.2
*
User-selectable
relay
contact
for
indications
of
drive
running,
drive
faulted,
or
drive
at
selected
speed
*
User-selectable
power-up
start,
auto-restart,
and
coast-to-rest
or
ramp-to-rest
stop
functions
*
User-selectable
local
or
remote
operation
*
29
user-adjustable
software
parameters
Drive
Description
The
SP500
drive
is
an
AC
PWM
(pulse-wicth-modulated)
inverter
that
operates
on
single-
or
three-phase
power.
See
figures
2.1
and
2.2.
AC
input
power
is
applied
to
the
drive’s
input
terminals.
Voltage
transients
are
suppressed
by
three
metal-oxide-varistor
(MOV)
suppressors.
These
suppressors
keep
any
input
voltage
transients
within
the
maximum
voltage
rating
of
the
input
diode
module.
The
input
diode
module
rectifies
the
incoming
AC
voltage
into
a
constant
DC
bus
voltage
which
is
filtered
by
the
DC
bus
capacitor
bank.
An
internal
DC-to-DC
power
supply
uses
power
from
the
DC
bus
and
provides
the
necessary
voltages
required
by
the
drive.
Under
regulator
software
control,
the
IGBT
(insulated-gate
bipolar-transistor)
inverter
bridge
converts
the
constant
DC
voltage
into
an
AC
PWM
waveform.
The
regulator
switches
the
IGBT
inverter
bridge
using
a
4, 6,
or
8
KHz
carrier
frequency
(user-selectable).
A
low
carrier
frequency
maximizes
the
power
rating
of
the
drive
but
also
increases
acoustic
noise.
A
high
carrier
frequency
selection
reduces
acoustic
noise
but
results
in
a
derating
of
the
drive’s
efficiency.
The
volts
per
hertz
(V/Hz)
regulator
governs
the
open-loop
operation
of
the
drive
for
adjustable-speed
performance
of
AC
induction
and
synchronous
motors.
The
regulator
maintains
a
ratio
of
voltage
to
output
frequency
that
provides
constant
or
variable
torque
across
a
wide
speed
range.
Drive
operation
can be
adjusted
by
the
parameters
entered
through
the
keypad.
A
microprocessor
on
the
Regulator
board
controls
drive
regulation.
See
figure
2.3.
The
Regulator
board
accepts
internal
power
feedback
signals
and
an
external
speed
reference
signal.
The
Regulator
board
provides
display
data
for
a
four-character
display,
which
is
used
to
indicate
drive
parameters,
parameter
values,
and
fault
codes.
The
drive
can be
controlled
either
locally
through
the
keyboard
and
display
(see
section
7)
or
remotely
through
the
terminal
strip
(see
section
5).
The
drive
is
intended
to
operate
trip-free
under
any
condition.
The
drive
uses
selected
signals
to
extend
the
acceleration
(starting)
and
deceleration
(stopping)
rates
of
the
motor
when
an
overcurrent
condition
occurs.
When
a
fault
does
occur,
however,
the
regulator
generates
an
instantaneous
electronic
trip
(IET)
signal
to
turn
the
drive
off
(coast-to-rest).
The
drive
stores
an
indication
or
record
of
the
IET
fault,
which
can be
viewed on
the
four-character
display.
After
a
fault,
the
STOP/RESET
key
ora
user-supplied
IET
RESET
pushbutton
must
be
pressed
to
reset
the
IET
signal
and
clear
the
fault
from
the
drive.
SP500
AC
Drive
Installation
and
Operation
Manual
Version
3.1

Table of Contents

Related product manuals