Record
of
User
Settings
Parameter
Default
No.
Parameter
Name
Range
Step
Size
Setting Setting
Date
F-00
Control
Source
Select
0,1,2,3
N/A
0
F-01
Accel
Time
(seconds)
0.5
-
90.0
0.10
5.0
F-02
Decel
Time
(seconds)
0.5
-
90.0
0.10
5.0
F-03
Minimum
Speed
(Hz)
0.5
-
30.0
0.10/0.25
5.0
F-04
Maximum
Speed
(Hz)
30.0
-
240.0
0.10/0.25
60.0
F-05
Current
Limit
(%)
10
-
150
1.0
150
F-06
Manual
Torque
Boost
(%)
2-10
1.0
2
F-07
V/Hz
Base
Speed
(Hz)
3
-
240
1.0
60
F-08
RPM
at
Base
Speed
10
-
9999
1.0
1750
F-09
Configurable
Output
Relay
Select
0,1,2
N/A
0
F-10
Carrier
Frequency
(kHz)
4,
6,8 N/A
4
F-11
Remote
Reference
Gain
(%)
60
-
100
0.10
100
F-12
Remote
Reference
Offset
(%)
0-40
0.10
0
F-13
Percent
Selected
Speed
ON,
OFF
N/A
OFF
Reference
Display
Enable
F-14
Electronic
Thermal
Overload
(%)
20
-
100
1.0
100
F-15
Electronic
Thermal
Overload
ON,
OFF
N/A
ON
Enable
F-16
Coast
Stop
Enable
ON,
OFF
N/A
ON
F-17
Reverse
Disable
ON,
OFF
N/A
OFF
F-18
RPM
Setpoint
Enable
ON,
OFF
N/A
OFF
F-19
Power-Up
Start
Enable
ON,
OFF
N/A
OFF
F-20
Password
Lockout
Enable
ON,
OFF
N/A
OFF
F-21
Avoidance
Frequency
(Hz)
Min
speed
-
0.10
5
Max
speed
F-22
Avoidance Bandwidth
(Hz)
0.0
-
30.0 0.10
0
F-23
Multi-Speed
Preset
1
(Hz)
Min
speed
-
0.10
20
Max
speed
F-24
Multi-Speed
Preset
2
(Hz)
Min
speed
-
0.10
20
Max
speed
F-25
Multi-Speed
Preset
3
(Hz)
Min
speed
-
0.10
20
Max
speed