Table
2.2
-
Power
and
NEMA
Enclosure
Ratings
(Continued)
Input
Power Power
Model
and
Horsepower
NEMA
Enclosure
AC
Input}
Input Input
Output};
Loss
Number
Rating*
Rating
Size**
Volts
Amps
KVA_
Amps*|
Watts***
1SU51002
Three-Phase
-
2
HP
1
B
575
3.4
3.3
2.7
90
1SU54002
Three-Phase
-
2
HP
4Xx/12
B
575
3.4
3.3
2.7
90
1SU51003
Three-Phase
-
3
HP
1
B
575
5.2
5.1
43
120
1SU54003
Three-Phase
-
3
HP
4x/12
B
575
5.2
5.1
4.3
120
1SU51005
Three-Phase
-
5
HP
1
B
575
7.5 7.5 6.2
150
1SU54005
Three-Phase
-
5
HP
4x/12
B
575
7.5 7.5 6.2
150
1SU51007
Three-Phase
-
7.5
HP
1
Cc
575
10.9 10.9
9.0
180
1SU54007
Three-Phase-7.5HP
4X/12
Cc
575
10.9 10.9
9.0
180
1SU51010
Three-Phase
-
10
HP
1
Cc
575
14.5 14.4 12.0
250
1SU54010
Three-Phase-10HP
4X/12
Cc
575
14.5 14.4 12.0
250
To
properly
size
the
drive
for
motor
nameplate
horsepower
and
amps,
refer
to
section
3.5
for
more
information.
Derating
for
4,
6,
8kHz
carrier
frequencies
is
not
required
except
for
the
units
indicated.
*
Refer
to
section
2.3.2
for
more
information
on
enclosure
sizes.
**
Full-load
at
all
carrier
frequencies.
Refer
to
section
3.1.3
for
more
information.
2.3.2
Enclosure
Ratings
and
Sizes
2.4
Each
of
the
SP500
drives
have
one
of
the
following
NEMA
ratings:
NEMA
Rating
Description
1
Vented.
For
general-purpose
indoor
applications.
4X/12
|Not
vented.
Supplied
with
base
and
keypad
gaskets.
For
use
in
indoor
environments
that
require
a
water-tight
and
dust-tight
enclosure.
An
enclosure
with
this
NEMA
rating
encompasses
both
ratings
(4X
and
12).
12
Intended
for
use
in
indoor
environments
that
require
a
dust-tight
and
drip-tight
enclosure.
See
table
2.2
for
listing
of
drive
model
numbers
and
their
individual
NEMA
ratings.
For
clarity
in
this
manual,
SP500
drive
enclosures
are
identified
by
size
as
enclosures
A
through
D.
Refer
to
table
2.2
for
a
listing
of
the
drive
model
numbers
and
their
individual
enclosure
sizes.
Refer
to
section
3.1.1
for
the
dimensions
of
enclosures
A
through
D.
Component
Locations
Figures
2.5
through
2.8
show
the
main
components
of
the
SP500
drives
(enclosures
A
through
D).
Appendix
F
lists
replacement
parts.
2-8
SP500
AC
Drive
Installation
and
Operation
Manual
Version
3.1

Table of Contents