8.3
Parameter
Descriptions
F-00
Control
Source
Select
This
parameter
selects
Parameter
Range:
0=
Local
control;
control
signals
and
speed
reference
from
the
drive
control
the
keypad
source
and
speed
reference
source.
1
=
Remote
control;
control
signals
from
the
terminal
strip;
speed
reference
from
the
analog
input
2=
Remote
control;
control
signals
from
the
terminal
strip;
speed
reference
from
the
keypad
3=
Remote
control;
control
signals
from
the
terminal
strip;
multi-speed
presets
from
the
terminal
strip
Default
Setting:
0=
Local
control
Step
Size:
N/A
When
F-00
=
0,
the
drive
responds
to
sequencing
commands
(start,
stop,
forward,
reverse)
from
only
the
keypad.
When
F-00
=
1,
2,
or
3,
the
drive
responds
to
sequencing
commands
from
the
terminal
strip.
Note
that
the
drive
will
respond
to
the
stop
command
from
the
keypad
regardless
of
the
value
in
this
parameter.
Refer
to
the
F-23
to
F-25
Multi-Speed
Presets
parameter
description
for
more
information
about
multi-speed
presets.
F-01
Acceleration
Time
This
parameter
Parameter
Range:
0.5
to
90
seconds
specifies
the
amount
of
time
it
takes
the
motor
to
ramp
from
Step
Size:
0.10
seconds
stop
to
the
maximum
speed
setting
in
F-04.
Default
Setting:
5.0
seconds
If
the
setpoint
frequency
requested
from
the
keypad
(using
the
and
W
keys)
is
less
than
the
maximum
speed
setting,
the
time
to
ramp
to
that
frequency
will
be
proportionally
less
than
the
actual
rate
setting.
For
example,
if
F-04 =
60Hz
and
F-01
=
4
seconds,
it
will
take
2
seconds
to
ramp
to
a
frequency
reference
of
30
Hz.
Note
that
if
the
acceleration
rate
is
set
too
fast,
an
overcurrent
fault
may
occur
(OC
will
be
displayed).
F-02
Deceleration
Time
This
parameter
Parameter
Range:
0.5
to
90
seconds
species
me
amour
Default
Setting:
5.0
seconds
to
ramp
from
the
Step
Size:
0.10
seconds
maximum
speed
setting
in
F-04
toa
stop.
Programming
Reference
8-5