Step
7.
Verify
the
direction
of
the
motor
shaft
rotation.
If
it
is
incorrect
for
your
application,
use
the
following
procedure
to
change
the
direction
of
rotation.
If
it
is
correct,
go
to
step
8.
a.
Press
the
STOP/RESET
key
to
stop
the
drive.
b.
Wait
until
the
motor
has
completely
stopped.
c.
Turn
off,
lock
out,
and
tag
power
to
the
drive.
Wait
five
minutes.
d
.
Remove
the
cover
and
check
the
DC
bus
potential
with
a
voltmeter
as
described
in
section
9.1.
Verify
that
the
DC
bus
capacitors
are
discharged.
Replace
the
cover.
e.
Reverse
any
two
of
the
three
motor
power
leads
(U,
V,
or
W).
f.
Turn
the
power
on.
g.
Press
the
START
key
and
verify
the
direction
of
rotation.
Step
8.
Using
the
@â„¢
and
“W
keys,
run
the
motor
without
any
load
across
the
speed
range.
If
the
motor
does
not
operate
satisfactorily,
check
the
parameter
settings.
Refer
to
chapter
8.
Step
9.
Press
the
STOP/RESET
key
to
stop
the
drive.
Step
10.
Turn
off,
lock
out,
and
tag
power
to
the
drive.
Wait
five
minutes.
Remove
the
cover
and
check
the
DC
bus
potential
with
a
voltmeter
as
described
in
section
9.1.
Verify that
the
DC
bus
capacitors
are
discharged.
Replace
the
cover.
Step
11.
Couple
the
driven
equipment
to
the motor.
Step
12.
Turn
power
on.
Step
13.
Press
the
START
key.
Step
14.
Run
the
drive
across
the
required
speed
range
under
load.
If
the
motor
does
not
rotate
at
minimum
speed,
increase
the
manual
torque
boost
(F-06).
Step
15.
If
the
drive
operates
the
motor
properly,
go
to
step
16.
If
the
drive
does
not
operate
the
motor
properly,
follow
the
steps
below:
a.
Refer
to
chapter
9,
Troubleshooting
Reference,
if
any
fault
codes
were
displayed
during
start
up.
b.
Verify
the
parameter
settings
again.
Step
16.
If
the
drive
operates
the
motor
properly:
a.
Press
the
STOP/RESET
key
to
stop
the
drive.
b.
Record
the
parameter
settings
in
Appendix
B.
Completing
the
Installation
6-3