Table
9.2
Resistance
Checks
for
Input
Diodes
Meter
Input
Connection
; ; ;
Diode
Component
is
OK
if
Component
is
No.
(+)
(-)
resistance
(R)
is:
defective
if:
1
*
R/L4
50
<R
<10Megohm
Continuity
(short
circuit)
or
open
when
the
meter
is
2
.
S/L2
connected
with
reversed
larity.
3
*
TIL3
polarity
4
R/L1
**
5
S/L2
**
6
T/L3
**
*
(+)
DC
bus
volts
power
terminal
**
(_)
DC
bus
volts
power
terminal
Table
9.3
Resistance
Checks
for
IGBTs
Meter
Connection
. . ;
IGBT
Component
is
OK
if
Component
is
No.
(+)
(-)
resistance
(R)
is:
defective
if:
1
*
W/T3
50
<R<10Megohm
Continuity
(short
circuit)
or
;
open
when
the
meter
is
2
v/T2
connected
with
reversed
3
:
UT
polarity.
4
W/T3
5
V/T2
*
6
U/T1
*
*
(+)
DC
bus
volts
power
terminal
**
(_)
DC
bus
volts
power
terminal
9-8