Parameter Descriptions
12-27
Specifies which analog input signal is being used as a trim input.
See figure 12.11.
117 Trim In Select
Range: 1 = Analog In 1
2 = Analog In 2
3-8 = Reserved
9 = MOP Level
10 = Reserved
11 = Preset Spd 1
12 = Preset Spd 2
13 = Preset Spd 3
14 = Preset Spd 4
15 = Preset Spd 5
16 = Preset Spd 6
17 = Preset Spd 7
18 = Local OIM
19 = DPI Port 2
20 = DPI Port 3
21 = Reserved
22 = Network
23 = Reserved
Default: 2 = Analog In 2
Access: 2 Path: Speed Command>Speed Trim
See also: 90
Figure 12.11 – Trim Input Select
Select
(117)
(118)
+
+
Reference A Trimmed Reference A