3-12
SP600 AC Drive User Manual
3.2 Mounting the Drive
Refer to figures 3.4 and 3.5 for drive mounting dimensions. See
figures 3.9 to 3.12 for flange-mount cutout dimensions. AutoCad
dimension drawings (.dxf) can be obtained from the
www.reliance.com website.
Attach the drive to the vertical surface using the mounting holes
provided.
Panel-mount drives: Drives should be mounted using 10-32 bolts.
Use washers under the bolt heads.
Flange-mount drives: Use the fasteners supplied with the drive.
Figure 3.9 – A-Frame Flange-Mount Cutout Dimensions
127,0
(5.00)
197.9
(7.80)
156,0
(6.14)
6,9
(0.27)
140,7
(5.54)
70,7
(2.78)
210,6
(8.29)
225,8
(8.89)
105,3
(4.15)
5.0
(0.20)
8x:
3,5
(
0.14)
4x: 3,0R
(0.12R)
58,8
(2.31)