EasyManua.ls Logo

Rockwell Automation Reliance electric SP600 Series - Figure 6.5 - Power Terminal Block; Figure 6.6 - Power Input Terminals on the Internal RFI Filter Option

Rockwell Automation Reliance electric SP600 Series
300 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6-8
SP600 AC Drive User Manual
Terminal Description Notes
R R (L1) AC line input power
S S (L2) AC line input power
T T (L3) AC line input power
+DC
1
or
BR1
1
Early versions of the power terminal block are labeled +DC and BRK.
Later versions are labeled BR1 and BR2.
DB (+) Dynamic brake resistor connection (+)
BRK1
1
or
BR2
DB (-) Dynamic brake resistor connection (–)
U U (T1) To motor
V V (T2) To motor
W W (T3) To motor
PE PE Ground
PE PE Ground
-DC DC Bus (-)
May be located to the left or right of the
Power Terminal Block.
Figure 6.5 – Power Terminal Block
L1
R
L2
S
L3
T
BR1
+DC
BR2
BRK
T1
U
T2
V
T3
W
PE PE
-DC
-DC
Frames A-D Power Terminal Block and DC Bus Test Points
L1
R
L2
S
L3
T
+DC –DC BR1 BR2 T1
U
T2
V
T3
W
Frame E Power Terminal Block
Figure 6.6 – Power Input Terminals on the Internal RFI Filter Option
L1
R
L2
S
L3
T
BR1
+DC
BR2
BRK
T1
U
T2
V
T3
W
PE PE
-DC
-DC
L1
R
L2
S
L3
T

Table of Contents