Parameter Descriptions
12-61
Displays the present operating status of the drive.
209 Drive Status 1
Range: See figure12.30
Default: Read Only
Access: 2 Path: Utility>Diagnostics
See also: 210
Figure 12.30 – Drive Status 1 (209)
0110000101110000
10 01234567891112131415
1=Condition True
0=Condition False
x =Reserved
Bit #
Ready
Active
Command Dir
Actual Dir
Accelerating
Decelerating
Alarm
Faulted
At Speed
Local ID 0
(1)
Local ID 1
(1)
Local ID 2
(1)
Spd Ref ID 0
(2)
Spd Ref ID 1
(2)
Spd Ref ID 2
(2)
Spd Ref ID 3
(2)
Nibble 1Nibble 2Nibble 3Nibble 4
Bits
(2)
Description
Bits
(1)
Description15 14 13 12 11 10 9
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Ref A Auto
Preset 1 Auto
Preset 2 Auto
Preset 3 Auto
Preset 4 Auto
Preset 5 Auto
Preset 6 Auto
Preset 7 Auto
TB Manual
Port 1 Manual
Port 2 Manual
Port 3 Manual
Port 4 Manual
Port 5 Manual
Port 6 Manual
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
Port 0 (TB)
Port 1
Port 2
Port 3
Port 4
Port 5
Port 6
No Local Control
Bit Function Description
8 At Speed Output frequency equal setpoint frequency.
7 Faulted Drive fault active.
6 Alarm Drive alarm active.
5 Decelerating Drive decelerating.
4 Accelerating Drive accelerating.
3 Actual Dir Operating motor direction
2 Commanded Dir Direction selected by the user.
1 Active Drive is outputting voltage.
0 Ready Drive is ready; no faults or inhibits, waiting
for valid start.