17
allow „forced arming”. If this occurs, the control panel will report “fail to auto arm” code and
the system/partition will not arm for a new inactivity time.
The type of autoarming is “regular” or “stay” and is dependent on the appropriate options
within [25] and/or [26] sections.
Program the inactivity autoarming times as they are described in [47] and [48] sections.
„INSTANT STAY ARMING
[*][1][User Code] or [INST][STAY][User Code],
where [INST] and [STAY] are the keys labeled „INSTANT” and „STAY”
This method is useful for perimeter protection and it allows the users to remain in the
protected area while the system/partition is “instant stay armed”. At the end of the exit delay
time, after such an arming mode, the zones which are usually of the perimeter delayed type
will respond as the instant zones (they will trigger the alarm as soon as they will be violated).
Thus any user can stay inside the protected area, but no one should come in from outside (for
example this arming mode is useful for the system/partition arming during the night when the
users are going to sleep and expect no guests; thus, entry/exit points like doors and windows
are armed while other zones like motion detectors remain deactivated).
While the green READY LED is ON or blinking, in order to arm the system/partition in an
„instant stay mode”, simply key in a valid user code within one of the previous
sequences. For each key pressing, the keypad buzzer will sound a short beep. The user
code must have the right of stay arming”.
If after entering the last digit of the user code the keypad buzzer is sounding a long rejection
beeps means:
- The user code was not correct; press [#] key and then key in again the user code
within one of the previous sequences.
- The user code hasn’t the right of “stay arming”; enter a user code with this right.
- The user code is entered while the green READY LED is OFF; all perimeter zones which
don’t allow „forced arming” feature must be closed when the system/partition is stay
armed.
- The user code is entered while the green READY LED is blinking but the code hasn’t the
right of force arming; all perimeter zones must be closed when the system/partition
is stay armed by such a user code.
After entering a valid user code within one of the previous sequences, all keypad
LEDs will be ON for a little while and the keypad buzzer will sound 6 acceptance beeps. Then,
the exit delay timer will start and the red ARMED LED will turn fast blinking. In the
same time the control panel will automatically bypass the interior zones (the zones
inside the objective that have the „stay” attribute activated by programming; the zones that
have not the „stay” attribute activated are called perimeter zones).
If the buzzer warnings were enabled by programming, during the exit delay the keypad
buzzer will sound warning beeps.
During the exit delay the yellow SYSTEM LED will blinking in case there are troubles in the system
(„AC power loss”, „low voltage on battery”, fail to communicate event”, „BELL trouble”, “phone line
trouble” or „system date and hour loss”) and the orange BYPASS LED will be ON in case at least
one interior zone is going to be bypassed by the panel (and/or at least one zone was
previously bypassed by the users); the orange BYPASS LED will turn OFF only when
disarming.
If during any home arming period at least one alarm or trouble occurs in the system, the
SYSTEM LED will start to blink. Because the alarm memory is cleared only upon another
system/partition arming, after at least one alarm occurred, the yellow SYSTEM LED will stop
to blink only upon another system/partition arming.
After the exit delay elapsed, the READY LED will turn OFF and the red ARMED LED will
keep fast blinking until disarming, signaling the system/partition is perimeter and
instant armed (while the system was armed in „instant stay mode”, the zone which are
usually of the perimeter delayed type will respond as the instant ones).
Because during such an arming period the access into the building isn’t allowed through the
zones which usually are of delayed type, at least a user must remain inside the building to
disarm the system/partition.
Notes: