• 2 real partitions which can be armed/disarmed independently from each other –
allowed by user rights;
• Individually programmable exit and entry delay times for each partition – allowed
by programming;
• Programmable alarm type: silent or audible and for audible alarms steady or pulsing;
• Individual siren timers for burglary and fire alarms;
PGM FUNCTIONS
• 2 programmable outputs, each with 18 options: “Any alarm latch”, “Follow system
status” (ON while system/partition is armed / OFF while system/partition is disarmed),
“Entry delay”, “Exit delay”, “System troubles”, „Auxiliary siren”, “Silent alarm latch” “Panic
alarm latch”, “Fire alarm latch”, “Medical emergency alarm latch”, “Latch on tamper alarm”,
“Pulse on Telephone Line Troubles”, “Retriggerable mono-stable” , “Pulse on arming”, “Pulse
on disarming”, “Bi-stable” “Clock timer” and “Latch on Communication Failure to CS”;
MONITORING OF SYSTEM TROUBLES
• Battery Voltage and AC power monitoring;
• Siren monitoring (upon disconnection or overload);
• „AUX overload” monitoring;
• Option of telephone line monitoring (TLM);
• Zone and keypad tamper openings.
SYNTHESIS SOUND COMMUNICATOR
• Capability of response to the remote calls for system status interrogation (the
system status -armed/disarmed/alarm/”AC power loss” – will be reported by specific
synthesis sounds);
• Programmable options of responses to the remote calls for system status
interrogation, either after „double call” or after programmable number of rings;
• Programmable option of automatic initiating the reporting the specific synthesis
sounds to the follow me phone numbers, when alarms and „AC power loss” event occur in
the system;
• Phone line tone detection upon the automatic initiating the synthesis sound reporting;
• Up to 4 follow me phone numbers (for the control panel to automatic report on the
phone line the „alarm” and „AC power loss” events, by specific synthesis sounds);
MISCELLANEOUS
• Zone tamper activates BELL output when system/partition is disarmed.
• Real clock timer which will stamp the 425 events in LOG;
• „Quick arming” options: „away quick arming”, „quick stay arming” and „quick instant
stay arming” – individually allowed by programming for each partition;
• Options of arming by users: „away arming”, „stay arming” and „instant stay arming” –
allowed by user rights;
• Autoarming options: „timed autoarming” and „inactivity autoarming” – individually
allowed by programming for each partition;
• Autodisarming option: „timed autoarming” – individually allowed by programming for
each partition;
• Option: the system (or each partition independently) automatically switches to stay
arming mode after any regular arming (by user, by PC or by keyswitch), if the user doesn’t
leave the protected area through any exit point during the exit delay;
• Option: no beeps/dings during the exit delay of stay arming modes – individually
allowed by programming for each partition;
• Option: Autoarming programmable in regular or home mode – individually allowed by
programming for each partition;
• Option: dings (audible sounds on the siren) on arming/disarming – individually allowed by
programming for each partition;
• Audible warnings for 3 minutes before timed autoarming: 3 minutes before timed
autoarming on the keypad buzzer and ding sounds optionally.