43
|__|__|__||__|__|__| |030||030| by default
The default entry delay times are both 30 seconds.
After the first 3 digits, the keypad buzzer will sound 3 beeps and after the last 3 digits it will
sound 6 beeps; the panel exits the section and will wait for a new command to enter another
section.
Press [#] key instead of the 3 corresponding digits if modifying of any timing is no longer
desired.
To exit the „main programming menu”, press [#] key.
Example: If the „entry delay 1” is to be set to 10 sec. and the „entry delay 2” is to be unchanged, enter: |010||#|.
After the first 3 digits the keypad buzzer will sound 3 beeps and after [#] key, the keypad buzzer will sound 6
confirmation beeps and the panel exits the section, waiting for a new command to enter another section. To exit the
„main programming menu”, press [#] key gain.
Notes:
1. The “entry delay 1 timer” applies to all zones defines as “delayed 1” type and the “entry delay 2 timer” applies
to all zones defines as “delayed 2” type; if partitioning was allowed by programming within [20] section, each
entry delay time applies to the partition which has assigned the respective delayed zones and if partitioning was
not allowed, both entry delay times apply to the system.
2. The entry delay times set the periods of time permitted between the first violation of any delayed zone and the
system/partition disarming. Once the system/partition is armed, first violation of the delayed zones will start
the appropriate entry-delay timer, giving to the user enough time to enter the premise and to disarm the
system/partition. The user must disarm the system/partition before the appropriate entry-delay timer elapses
or the system will generate an alarm. If a delayed zone triggers the alarm, the system or the appropriate
partition will switch to an instant working mode which will be signaled by a fast blinking of the corresponding
ARMED LED (the alarm was once triggered by a delayed zone and all the zones usually of delayed type will
respond as instant type in the respective partition).
3. For the entry delay 1 and 2 timers any value from 000 to 999 may be entered, but the panel will automatic
adjust the introduced value by modulo 256 and will record the result in memory as programmed
value. If the result of adjustment is 0 (the entry delay is set at 0), the zone which is usually of delayed type
will respond as instant type and will trigger the alarm once it is violated. So, when any user enters the
protected area through the delayed zone to disarm the system/partition, unexpected alarms may be
triggered by this zone!
SECTION [31] - EXIT DELAY 1 / EXIT DELAY 2 TIMERS
While system is being within „main programming menu”, to set the exit delay 1 and 2
timers, you should select section [31] and then enter 2 groups of 3 digits each (001
to 255 seconds).
The following sequence will be introduced:
|__|__|__||__|__|__| |060||060| by default
The default exit delay times are both 60 seconds.
After the first 3 digits, the keypad buzzer will sound 3 beeps and after the last 3 digits it will
sound 6 beeps; the panel exits the section and will wait for a new command to enter another
section.
Press [#] key instead of the 3 corresponding digits if modifying of any timing is no longer
desired.
To exit the „main programming menu”, press [#] key.
After entering the required arming sequence (i.e. any valid user code entering), the exit delay
parameters determine the amount of times a user has to leave the protected area before the
panel arms the partition (or the entire system).
Example: If the „exit delay 1” is to be set to 20 sec. and the „exit delay 2” is to be unchanged, enter: |020||#|. After
the first 3 digits the keypad buzzer will sound 3 beeps and after [#] key, the keypad buzzer will sound 6 confirmation
beeps and the panel exits the section, waiting for a new command to enter another section. To exit the „main
programming menu”, press [#] key gain.
Notes:
1. For the exit delay timers any value from 000 to 999 may be entered, but the panel will automatic adjust the
introduced value by modulo 256 and will record the result in memory as programmed value. If the
result of adjustment is 0, the appropriate “exit time” is 0 and after any valid user code entering for
system/partition arming may cause unexpected alarms!
2. Each exit delay time applies to all zones in the selected partition as follows:
- If partitioning was allowed by programming within [20] section, the „exit delay 1” applies to all zones in the
first partition and the „exit delay 2” applies to all zones in the second partition;
- If partitioning was not allowed by programming within [20] section, the „exit delay 1” applies to all zones in
the system and the „exit delay 2” will be no longer considerate by the panel.