37
SECTION [20] 1
-ST
SET OF GENERAL SYSTEM OPTIONS
While the system is within „main programming menu”, to establish the 1
-st
set of General
System Options select section [20].
Once the panel entered section [20] the keypad buzzer will sound 3 confirmation beeps and
the panel will display the 1
-st
set of General System Options, according to the table bellow:
Keypad LEDs’ status while the system is within 1
-st
set of General System Options displaying submenu
ON
OFF
Blinking
ON
OFF
ON
OFF
enabled
disabled
*
keypad lockout after to many wrong codes
enabled
disabled
*
default reset locked
enabled
disabled
*
partitioning
maintained
momentary
*
keyswitch type
upon zone closes back
*
upon bell cut-off time
zone restoration
enabled
disabled
*
report disarm only after alarm
enabled
disabled
*
keypad panics with siren
enabled
disabled
*
keypad emergency with siren
Note: The default programmed options are marked with *.
In order to activate / deactivate any of these options, press 1 to 8 keys. The
corresponding zone LED will turn ON / OFF accordingly.
If these options should keep their previously programmed values press [#] key instead of any
numerical key.
After establishing these options to the required values press [#] key to confirm. The
keypad buzzer will sound 6 beeps and exit this section, waiting for a new command to enter
another section or to exit the programming menu.
Notes:
1. “Zone restoration” is applying to any zone that triggered the alarm and to the time moment when
the restoration event will be memorized in the 425-event LOG.
2. The programmed value of the “zone restoration parameter is the same for all zones. According to
the option selected by programming, the “restoration event” will be memorized as a son as either the zone
loop is closing backor the siren timer has expired.
3. Any zone having the attribute “swinger shutdown enabled will trigger at most 3 alarms during
one arming period (or during one disarming period for 24h zones), irrespective of programmed value of the
“zone restoration” option.
4. The restoration events for silent zones will be memorized in the 425-event LOG as a son each zone loop
close back”.
5. If any zone remains “open after it triggered the alarm, the restoration event for that zone will be
memorized in the 425-event LOG as soon as the zone loops „close back”.
SECTION [21] 2
-ND
SET OF GENERAL SYSTEM OPTIONS
While the system is within „main programming menu”, to establish the 2
-nd
set of General
System Options select section [21].
Once the panel entered section [21] the keypad buzzer will sound 3 confirmation beeps and
the panel will display the 2
-nd
set of General System Options, according to the table bellow:
Keypad LEDs’ status while the system is within 2
-nd
set of General System Options displaying
submenu
ON
OFF
Blinking
ON
OFF
ON
OFF
enabled
disabled
*
case tamper of keypad 1
enabled
disabled
*
case tamper of keypad 2
enabled
disabled
*
case tamper of keypad 3

Table of Contents

Related product manuals