Note: The PGM1 as “clock timer” will deactivate only if the entered data was valid; the value for hour [hh] is between
0 and 23 and the value for minute [mm] is between 0 and 59.
SECTION [53] – ACTIVATION MOMENT FOR PGM2 AS “CLOCK TIMER” (HOUR:MINUTE)
Enter 2 groups of 2 digits, the first 2 digits for the hour (00 to 23) and the second 2 digits for
the minute (00 to 59); in this way will be set the daily moment when the PGM2 defined as
„clock timer” type is activating automatically.
The following sequence will be introduced:
|__|__||__|__| not programmed by default
The keypad buzzer will sound 3 beeps after the first 2-digit group and 6 beeps after the
second one. Then the panel exits the section and will wait for a new command to enter
another section.
To exit the „main programming menu”, press [#] key.
Note: The PGM2 as “clock timer” will activate only if the entered data was valid; the value for hour [hh] is between 0
and 23 and the value for minute [mm] is between 0 and 59.
SECTION [54] – DEACTIVATION MOMENT FOR PGM2 AS “CLOCK TIMER” (HOUR:MINUTE)
Enter 2 groups of 2 digits, the first 2 digits for the hour (00 to 23) and the second 2 digits for
the minute (00 to 59); in this way will be set the daily moment when the PGM2 defined as
„clock timer” type is deactivating automatically.
The following sequence will be introduced:
|__|__||__|__| not programmed by default
The keypad buzzer will sound 3 beeps after the first 2-digit group and 6 beeps after the
second one. Then the panel exits the section and will wait for a new command to enter
another section.
To exit the „main programming menu”, press [#] key.
Note: The PGM2 as “clock timer” will deactivate only if the entered data was valid; the value for hour [hh] is between
0 and 23 and the value for minute [mm] is between 0 and 59.
SECTION [55] – AUTO ARMING MOMENT FOR SYSTEM / PARTITION A (HOUR:MINUTE)
Enter 2 groups of 2 digits, the first 2 digits for the hour (00 to 23) and the second 2 digits for
the minute (00 to 59); in this way will be set the daily moment when the system / partition A
is arming automatically.
The following sequence will be introduced:
|__|__||__|__| not programmed by default
The keypad buzzer will sound 3 beeps after the first 2-digit group and 6 beeps after the
second one. Then the panel exits the section and will wait for a new command to enter
another section.
To exit the „main programming menu”, press [#] key.
Note: the system / partition A will auto arm only if the appropriate option was enabled by programming and if the
entered data was valid (the value for hour [hh] is between 0 and 23 and the value for minute [mm] is between 0 and
59).
SECTION [56] – AUTO DISARMING MOMENT FOR SYSTEM / PARTITION A (HOUR:MINUTE)
Enter 2 groups of 2 digits, the first 2 digits for the hour (00 to 23) and the second 2 digits for
the minute (00 to 59); in this way will be set the daily moment when the system / partition A
is disarming automatically.
The following sequence will be introduced:
|__|__||__|__| not programmed by default
The keypad buzzer will sound 3 beeps after the first 2-digit group and 6 beeps after the
second one. Then the panel exits the section and will wait for a new command to enter
another section.
To exit the „main programming menu”, press [#] key.