45
After the first 3 digits were entered, the keypad buzzer will sound 3 beeps and after the last 3
digits 6 beeps. Then the panel exits the section and will wait for a new command to enter
another section.
Press [#] key instead of the corresponding 3-digit group if one of the 2 timings isn’t to be
modified.
Notes:
1. These pulse durations are individually programmable for PGM1 and PGM2 and they establish the „activation
time” for all following PGM outputs defined as pulse types: “pulse on arming”, “pulse on disarming”,
“retriggerable mono-stable” and “pulse on phone line trouble”.
2. For each time activation for PGMs defined as pulse types any value from 000 to 999 may be entered, but the
panel will automatic adjust the introduced value by modulo 256 and will record the result in memory as
programmed value. If any result of adjustment is 0, the respective PGM defined as any pulse types
will activate only for 1 second!
SECTION [36] - RING NUMBER AFTER THAT THE CONTROL PANEL ANSWERS TO THE REMOTE CALLS
Enter 2 digits (01 to 99 rings) in order to establish the ring number that should be
emitted for the control panel to automatic answer to the remote calls - the remote
interrogation calls and / or the remote PC calls.
The following sequence will be entered:
|__|__| |10| by default
After the 2 digits, the keypad buzzer will sound 6 confirmation beeps and the panel exits the
section, waiting for a new command to enter another section.
Note: In order to be considered the ring number programmed in this section, the following conditions need to be met:
o „Answer after programmed rings number” option must to be selected within section [28], not the “double
call” option.
o At least one of the “Answering to PC calls” and “Answering to interrogation calls” options must to be set as
enabled within section [28].
SECTION [37] NUMBER OF SOUND DIALING SEQUENCES / TIME OF THE SOUND REPORTING
Enter 2 groups of 2 digits, the first being the number of times the synthesis sounds will be
repeated for the programmed phone numbers (01 to 99 sequences) and the second 2-digit
group being the time of the sound reporting (01 to 99 seconds).
The following sequence will be entered:
|__|__||__|__| |02||30| by default (02 sound dialing sequences / 30
sec.)
The keypad buzzer will sound 3 beeps after the first 2-digit group and 6 beeps after the
second one. Then the panel exits the section and will wait for a new command to enter
another section.
Remark: A sound dialing sequence consists of sending the synthesis sounds once to each of the programmed phone
numbers (up to 4 follow me phone numbers). After a sound dialing sequence was finished, the control panel will begin
the next sequence similarly until the sequence number programmed in this section was over.
Note: For the “number of sound dialing sequences” and “time of the sound reporting” you can set even the value 00.
Don’t program the value 00 for these parameters because the synthesis sounds will no longer be transmitted on
the phone line!
SECTION [38] TIME BETWEEN THE PERIODICAL TESTS (IN HOURS OR MINUTES)
Enter 1 group of 3 digits for time between the periodical tests (001 to 255 hours or minutes,
depending of the unit time for the time between periodical tests, programmed in [28]
section).
The following sequence will be introduced:
|__|__|__| by default 24 hours
The keypad buzzer will sound 6 confirmation beeps after the 3-digit group and the panel exits
the section, waiting for a new command to enter another section.
Press [#] key instead of the 3-digit group if you want to cancel programming of this time
interval.
To exit the „main programming menu”, press [#] key.
Note: For this time interval any value from 000 to 999 may be entered, but the panel will automatic adjust the
introduced value by modulo 256 and will record the result in memory as programmed value. If the result of
adjustment is 0, the periodical tests will be transmitted after every minute or hour!