EasyManua.ls Logo

ROEL CERBER C52 - SECTION [42] - EVENT REPORTING (ZONE RESTORE;KEYSWITCH;LOCKOUT); SECTION [43] - EVENT REPORTING (PC ARMING;AUTOARMING;QUICK ARMING); SECTION [44] - EVENT REPORTING (PARTIAL ARMING;POWER;BELL;SUPPLY TROUBLES); SECTION [45] - EVENT REPORTING (POWER;BATTERY;BELL;SUPPLY RESTORE)

ROEL CERBER C52
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
48
Timed Autoarming 34 [03]
Inactivity Autoarming 34 [04]
Quick Arming 34 [08]
Quick Stay Arming 34 [08]
Disarming By PC Software 14 [07]
Timed Auto Disarming 14 [03]
SECTION [44] EVENT REPORTING REGARDING: PARTIAL ARMING / FAIL TO AUTOARM / AC POWER
FAILURE / BATTERY FAILURE / BELL TROUBLE / “AUXILIARY SUPPLY TROUBLE / “TIME & DATE
INACCURATE
Partial Arming 34 [56]
Fail to Autoarm 14 [55]
AC Power Failure 13 [01]
Battery Failure 13 [02]
Bell Trouble 13 [21]
Auxiliary Supply Trouble 13 [AA]
Time & Date Inaccurate 16 [26]
SECTION [45] EVENT REPORTING REGARDING: AC POWER RESTORE / “BATTERY VOLTAGE RESTORE /
“BELL TROUBLE RESTORE / AUXILIARY SUPPLY RESTORE / “TIME & DATE REPROGRAMMED /
“PERIODICAL TEST REPORT
AC Power Restore 33 [01]
Battery Voltage Restore 33 [02]
Bell Trouble Restore 33 [21]
Auxiliary Supply Restore 33 [AA]
Time & Date Reprogrammed 36 [26]
Periodical Test Report 16 [02]
Note: If after the 8 attempts no central station answers, the control panel will record an Unsuccessful CS
Communication” event into the 425-event LOG. Upon a new reportable event occurring or upon phone line restore, the
entire list from CS internal buffer, the old and the new reporting codes which are already in the list will be reported
together to the CS.
SECTION [46] MOMENT FOR THE FIRST PERIODICAL TEST (HOUR:MINUTE)
Enter 2 groups of 2 digits, the first 2 digits for the hour (00 to 23) and the second 2 digits for
the minute (00 to 59) when the system will send the first periodical test.
The following sequence will be introduced:
|__|__||__|__| by default first periodical test is sent at 01
00
The keypad buzzer will sound 3 beeps after the first 2-digit group and 6 beeps after the
second one. Then the panel exits the section and will wait for a new command to enter
another section.
To exit the „main programming menu”, press [#] key.
Note: The periodical test will be performed only if the entered data was valid; the value for hour [hh] is between 0 and
23 and the value for minute [mm] is between 0 and 59.
SECTION [47] „INACTIVITY TIME AFTER THAT THE SYSTEM / PARTITION A WILL AUTO ARM (HOUR &
MINUTE)
Enter 2 groups of 2 digits; the first 2 digits for the number of hours (00 to 99) and the second
2 digits for the number of minutes (00 to 99) after that the system / partition A will auto arm
if no motion will be detected in the protected area.
The following sequence will be introduced:
|__|__||__|__| |03||00| by default (3 hours)
The keypad buzzer will sound 3 beeps after the first 2-digit group and 6 beeps after the
second one. Then the panel exits the section and will wait for a new command to enter
another section.
To exit the „main programming menu”, press [#] key.
Note: If in this section the 2 groups of 2 digits are set both with value 0, the system / partition A will try to auto arm