47
Whenever the system/partition is armed, the output goes to ground for the time programmed
in section [35].
[0E] PULSE ON DISARMING
When the system is disarmed, the output goes to ground for the time programmed in section
[35].
[0F] BI-STABLE
The output changes from activated to deactivated and the other way round for each command
[*][9].
[12] FIRE DETECTOR POWER SUPPLY
The output is all the time activated and changes from activated to deactivated for the time
programmed in section [35], each time partition/system is armed or disarmed.
SECTION [40] TO [45] EVENT REPORTING CODES IN CONTACT ID FORMAT:
Notes:
1. Any transmission to CS will use only CID format (4 account digits + 4 event digits + 2 partition digits + 3
zone/user digits).
2. By programming, you can change only the last 2 digits of any 4-event digit group.
3. If one CID code is not to be reported, enter 2 digits of [0] for last 2 digits of the 4 event digits.
4. If CID code is still to be reporting as [xx00], enter 2 digits of [A] for last 2 digits of the 4 event digits.
SECTION [40] EVENT REPORTING REGARDING: ARMING BY USER / „STAY ARMING BY USER /
„DISARMING BY USER / USER UNDER DURESS / AUTO ARMING CANCELLATION / KEYPAD TAMPER
ALARM / KEYPAD TAMPER RESTORE
Arming by User 34 [01]
Stay Arming by User 34 [41]
Disarming by User 14 [01]
User under Duress 11 [21]
Auto Arming Cancellation 34 [05]
Keypad Tamper Alarm 11 [45]
Keypad Tamper Restore 31 [45]
SECTION [41] EVENT REPORTING REGARDING: AUTO ZONE SHUTDOWN / “ZONE BYPASSED /
“BURGLARY ALARM / “TAMPER ALARM / “PANIC ALARM / “FIRE ALARM / „MEDICAL EMERGENCY
ALARM
Auto Zone Shutdown 15 [62]
Zone Bypassed 15 [70]
Burglary Alarm 11 [30]
Tamper Alarm 11 [44]
Panic Alarm 11 [20]
Fire Alarm 11 [10]
Medical Emergency Alarm 11 [AA]
Note: Upon arming the panel will transmit to CS the reporting code of zone bypassing, if there are in the system:
1. Bypassed zones by the panel in case of partial arming and the respective zones are as interior type and / or
2. Bypassed zones by the users using [*] [3] [User Code] or [BYPASS][User Code] commands.
SECTION [42] EVENT REPORTING REGARDING: ZONE ALARM RESTORE / “ZONE TAMPERED RESTORE /
“ARMING BY KEYSWITCH / DISARMING BY KEYSWITCH / “KEYPAD LOCKOUT / MODULE REMOVED /
“MODULE ADDED
Zone Alarm Restore 31 [30]
Zone Tampered Restore 31 [44]
Arming By Keyswitch 34 [09]
Disarming By Keyswitch 14 [09]
Keypad Lockout 14 [21]
Module Removed 15 [32]
Module Added 15 [31]
SECTION [43] EVENT REPORTING REGARDING: ARMING BY PC SOFTWARE / “TIMED AUTOARMING /
“INACTIVITY AUTOARMING”/ QUICK ARMING / “QUICK STAY ARMING / “DISARMING BY PC SOFTWARE /
“TIMED AUTO DISARMING
Arming By PC Software 34 [07]