2. In order to program the selected CS phone number, you should enter up to 15
digits as you would on a key phone.
2.1 The zone 1 and 2 LEDs will blink after first digit entering of a new sequence for
selected CS phone number. Means the control panel is waiting for the other digits for the
selected CS phone number.
2.2 HEX digits can be added inside the phone number (enter HEX digits A…F by
pressing [*] and [0…5] keys).
3. After the last digit of the phone number press [#] key to confirm and then the
control panel will go back within “main programming menu”.
4. In order to erase the selected CS phone number press [*] key, while the panel is
waiting for the first digit. The keypad buzzer will sound 6 confirmation beeps and the
control panel will go back within “main programming menu”.
SECTION [63] - PANEL IDENTIFICATION CODE UPON UPLOAD/DOWNLOAD
Enter 4 digits to identify the panel to the PC during upload/download process.
|__|__|__|__| |0|0|0|0| by default
After entering the 4 digits, 6 beeps will sound and the keypad will exit the section waiting for
a new command.
SECTION [64] - PC IDENTIFICATION CODE UPON UPLOAD/DOWNLOAD
Enter 4 digits:
|__|__|__|__| |0|0|0|0| by default.
This code is to identify the PC to the panel during upload/download process.
After the 4 digits, 6 beeps will sound and the keypad will exit the section waiting for a new
command.
SECTION [65] - ONLINE DOWNLOAD (PC PROGRAMMING ACCEPTANCE)
This command allows the installer to manually start the upload/download process.
Just entering section [65] will manually activate the communication between PC and the
panel. While the PC modem is already being on the phone line (PC is already calling the
control panel) the installer should just enter section [65] and the communication between PC
and panel is manually activated (the control panel will take over the phone line and will try to
communicate to the PC, which should already be on the phone line and calling the control
panel).
Notes:
1. This function is identical to the [*][8][Master Code][65][#] command, which is reserved for the master user.
2. This command is useful when the „Answering to PC calls” option is not enabled by programming but panel
programming by PC is still required.
3. This command is also useful in a local connection between PC modem and the panel (connection without a
phone line). In this case, use the connection below: