40
Keypad LEDs’ status while the system is within 2
-nd
set of 1
-st
Partition Options displaying submenu
ON
OFF
ON
OFF
enabled
disabled
*
timed autoarming
enabled
disabled
*
inactivity autoarming
enabled
*
disabled
beep on exit delay
enabled
disabled
*
Switch to stay arming if user does not exit
enabled
disabled
*
autoarmings are stayed type
enabled
disabled
*
force autoarmings
enabled
disabled
*
no beeps and dings on stay armings
enabled
disabled
*
timed autodisarming
Note: The default programmed options are marked with *.
In order to activate / deactivate any of these options, press 1 to 8 keys. The
corresponding zone LED will turn ON / OFF accordingly.
If these options should keep their previously programmed values press [#] key instead of any
numerical key.
After establishing these options to the required values press [#] key to confirm. The
keypad buzzer will sound 6 beeps and exit this section, waiting for a new command to enter
another section or to exit the programming menu.
SECTION [26] 2
-ND
SET OF 2
-ND
PARTITION OPTIONS
While the system is within „main programming menu”, to establish the 2
-nd
set of 2
-nd
Partition
Options select section [26].
Once the panel entered section [26] the keypad buzzer will sound 3 confirmation beeps and
the panel will display the 2
-nd
set of 2
-nd
Partition Options, according to the table bellow:
Keypad LEDs’ status while the system is within 2
-nd
set of 2
-nd
Partition Options displaying submenu
ON
OF
Blinking
ON
OFF
ON
OFF
enabled
disabled
*
timed autoarming
enabled
disabled
*
inactivity autoarming
enabled
*
disabled
beep on exit delay
enabled
disabled
*
switch to stay arming if user does not exit
enabled
disabled
*
autoarmings are stayed type
enabled
disabled
*
force autoarmings
enabled
disabled
*
no beeps and dings on stay armings
enabled
disabled
*
timed autodisarming
Note: The default programmed options are marked with *.
In order to activate / deactivate any of these options, press 1 to 5 keys. The
corresponding zone LED will turn ON / OFF accordingly.
If these options should keep their previously programmed values press [#] key instead of any
numerical key.
After establishing these options to the required values press [#] key to confirm. The
keypad buzzer will sound 6 beeps and exit this section, waiting for a new command to enter
another section or to exit the programming menu.
SECTION [27] 4
-TH
SET OF GENERAL SYSTEM OPTIONS (TELEPHONE OPTIONS)
While the system is within „main programming menu”, to establish the telephone options
select section [27].
Once the panel entered section [27] the keypad buzzer will sound 3 confirmation beeps and
the panel will display the telephone options, according to the table bellow:
Keypad LEDs’ status while the system is within telephone options displaying submenu