EasyManua.ls Logo

ROEL CERBER C52 - READY LED (KP-164 P) Status Details; SYSTEM LED Status Explanations; Bypass LED Functionality; ARMED A LED Status Indications

ROEL CERBER C52
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
READY LED (KP-164P)
a) While the entire system is armedOFF.
b) While at least one partition is disarmed or during the exit time:
ON the system is ready for arming (all zone loops are closed even those
which allow forced arming” feature);
Blinking the system is ready for arming (all zone loops are closed, except at
least one which allow forced arming” feature);
OFF at least one zone is open and it doesn’t allow forced arming” feature;
c) While the system is totally disarmed and finds itself within one of the Programming
Menus:
ON while the master user is in one of the master user’s programming
procedures, for modifying the user codes, the follow-me phone numbers or
the system date and hour, etc.;
ON while the installer is being within one of the system parameter
programming sections.
SYSTEM LED
A) While the system is:
Totally armed in away modeOFF;
At least one partition is armed in stay mode
Blinking in case there are recorded alarms during that stay armed period
and/or there are troubles in the system (“AC power loss”, “low battery
voltage”, fail to communicate event”, “BELL trouble”, “phone line trouble” or
“system date and hour loss”);
Only for KP-164P (SYSTEM LED is also used for the BYPASS LED functions):
ON if there is at least one zone manually bypassed by user and/or at least
one interior zone bypassed by control panel;
Alternate 3 seconds OFF, 3 seconds blinking if both conditions are
present, system troubles and/or registered alarm events and bypassed zones.
During any exit timeBlinking in case there are troubles in the system.
B) While the system is partially armed:
Blinking in case there are recorded alarms (during the previous armed period
or during present disarmed period for 24h zones) or there are troubles in the
system (“AC power loss”, “low battery voltage”, fail to communicate event”, “BELL
trouble”, “phone line trouble” or “system date and hour loss”);
Only for KP-164P (SYSTEM LED is also used for the BYPASS LED functions):
ON if there is at least one zone manually bypassed by user and/or at least
one interior zone bypassed by control panel;
Alternate 3 seconds OFF, 3 seconds blinking if both conditions are
present, system troubles and/or registered alarm events and bypassed zones.
C) While the system is totally disarmed:
Blinking when the user is being within one of the next menus: Zone bypassing,
System trouble displaying, Alarm memory displaying or Program/Modify of the user
codes, “follow-me” phone numbers or system date and hour;
Blinking while the installer is being within programming menu of the system
parameters.
Bypass LED (don’t apply for KP-164P)
ON there is at least one user-bypassed zone in the system or during stay arming mode in
case at least one zone has the attribute „stay enabled.
The LED will turn OFF upon system disarming or if the users unbypass all zones.
ARMED A LED
a) While the system / partition A is armed:
ON if the system / partition A is regularly armed;
Fast Blinkingif the system / partition A is armed in instant stay mode”.
Slow Blinkingif the system / partition A is armed in stay mode”.

Table of Contents

Related product manuals