EasyManua.ls Logo

Rohde & Schwarz FSEA20 - Page 144

Rohde & Schwarz FSEA20
438 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FSE CONFigure-Subsystem
1065.6016.12 6.87 E-16
CONFigure:SPURious Subsystem
This subsystem provides commands for configuring the measurements in the GSM BTS (FSE-K11) or
GSM MS (FSE-K10) Analyzer mode used for measuring the power of spurious emissions.
COMMAND PARAMETERS UNIT COMMENT
CONFigure
:SPURious
[:IMMediate]
:COUNt
:RXBand
:RANGe
:STEP<1..26>
:COUNt?
:ANTenna
--
<numeric_value>
<numeric_value>
TXBand | OTXBand | RXBand |
IDLeband | COMBined
<Boolean>
CONDucted | RADiated
--
--
--
--
--
no query, Option FSE-K11, FSE-K10
Option FSE-K11, FSE-K10
Option FSE-K11
Option FSE-K11, FSE-K10
Option FSE-K11, FSE-K10
query only
Option FSE-K10
:CONFigure:SPURious[:IMMediate]
This command selects measurement of spurious emissions.
Example: ":CONF:SPUR"
Features: *RST value: --
SCPI: device-specific
Modes: BTS, MS
This command is an event and has thus no query and no *RST value assigned.
:CONFigure:SPURious:COUNt 1 to 1000
This command sets the number of bursts used for determining the average and maximum values.
Example: ":CONF:SPUR:COUN 100"
Features: *RST value: 500 (GSM/DCS1800 phase I)
200 otherwise
SCPI: device-specific
Modes: BTS, MS
The number of bursts in measurements of the RX band is set by command
:CONFigure:SPURious:RANGe:RXBand (FSE K11 only).
:CONFigure:SPURious:COUNt:RXBand 1 to 1000
This command ses the number of bursts used for determining the average and maximum values in
measurements of the RX band.
Example: ":CONF:SPUR:COUN:RXB 100"
Features: *RST value: 1
SCPI: device-specific
Modes: BTS

Table of Contents

Related product manuals