EasyManua.ls Logo

Roland MV-8000 - 03 St. Dynamics Processor; Comp (Comp;Limiter); Enhan (Enhancer)

Roland MV-8000
460 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
403
Effect Block
Preset patches and Algorithm list Effect Block MIDI Implementation Specifications Index
03 St. Dynamics Processor
Comp (Comp/Limiter)
This effect is able to use as a compressor, which
controls inconsistencies in sound levels by
suppressing high sound levels while lifting weaker
signals, or as a limiter that prevents the signal from
reaching exceedingly high levels.
1.
Threshold
Value: -60–0 dB
Sets the volume level at which the compression
begins.
2.
Ratio
Value: 1:1.5, 1:2, 1:4, 1:100
Sets the “source sound:output sound” compression
ratio.
3.
Attack
Value: 0–100
Sets the time after the sound volume is crossed the
threshold level until compression begins.
4.
Release
Value: 0–100
Sets the time for compression to stop after the sound
falls back under the threshold level.
5.
Output Level
Value:-60–+12 dB
Sets the output volume.
When used as a limiter, set the Ratio to 100:1 with a
short release time. If the volume exceeds the
threshold level, the sound is suppressed instantly
detected as the excess input.
Enhan (Enhancer)
This effect regulates the high-end overtones,
clarifying the sound and the sound contour.
1.
Sens
Value:0–100
Sets the degree to which the Enhancer is applied.
2.
Freq
Value:1.0–10.0 kHz
Sets the lower limit of the frequencies to which the
enhancement effect is added.
3.
Mix Level
Value: 0–100
Sets the level of the overtones produced by the
Enhancer that is mixed in with the source sound.
4.
Output Level
Value: 0–100
Sets the output volume.