Operation
53 / 127
Operation
Start propulsion engine with ignition switched off:
►Actuate Start propulsion engine function switch for approx. 5 seconds.
The propulsion engine is started.
A speed change can only be made with an operational control unit.
Start propulsion engine with control unit switched off:
►Actuate Start propulsion engine function switch for approx. 5 seconds.
The propulsion engine is started.
A speed change can only be made with an operational control unit.
Start propulsion engine with defective control unit
Depending on the defect in the control unit the propulsion can be start-
ed.
►Actuate Start propulsion engine function switch for approx. 5 seconds.
The propulsion engine is started.
The engine speed is preset to 3500 min
-1
.
A speed change cannot be made in this mode.
► Actuate Priming pump function switch, to activate/deactivate the prim-
ing pump.
The priming pump is activated/deactivated.
Automatic monitoring and operation of the priming pump cannot be
carried out in this mode.
Immediately rectify any faults, to ensure the safety and operational readi-
ness.